Within the scope of the action, the currentcorroded distributor was dismantled and replaced by the new one. Thedistributor is situated on the roof of the pumping plant. The new distributorhas the same construction as the current one and it is placed on a newreinforced-concrete structure.

 

BasicTechnical Specifications:

  •         tar concentrate temperature                              75 ÷ 85 °C
  •         viscosity                                                          ca 0.60.10-3 Pa.s
  •         specific weight                                     1.01 ÷ 1.03 kg/dm3 
  •         diameter of the distributor                                ø 8,000 mm
  •         height                                                              5,400 mm

 

Subjectof the Job:

  •         production documentation

 